V. Luboz, E. Promayon, Y. Payan. Measurements of the linear elastic properties of the face soft tissues using an aspiration device. In 12th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering, CMBBE14, October 2014.

Download

Download paper: Adobe portable document (pdf)

Copyright notice: Disclaimer: this material is presented to ensure timely dissemination of scholarly and technical work. Files of articles may be covered by copyright. You may browse the articles at your convenience in the same spirit as you may read a journal or conference proceedings in a public library. Retrieving, copying, distributing these files, entirely or in parts, may violate copyright protection laws. Copyright and all rights therein are retained by authors or by other copyright holders. All person copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.

Abstract

Maxillo-facial surgeries have a direct impact on the face shape and appearance. The anatomical variations in the face soft tissues (skin thickness, skin or muscle material parameters...) make it hard to predict the face final shape accurately. Biomechanical modeling could help in this prediction by simulating the soft tissue displacement following the bone remodeling and therefore the patient's face visible outcome [1]. Measuring the variation of the skin properties across a range of subjects could help to build accurate patient-specific biomechanical simulations. In [2], the skin initial Young's modulus was evaluated to 23kPa using a Mooney Rivlin model and measurements on different locations on the face of one subject. In this study, a specifically designed aspiration device, called LASTIC (Light Aspiration device for in vivo Soft TIssue Characterization), is used to characterize the elastic modulus of the face soft tissues at four different locations (cheek, cheekbone, forehead, and lower lip) on 16 subjects. LASTIC is sterilizable and could therefore be used in the operating room. It is a two-compartment 33mm x 34mm metal cylinder using the aspiration technique to estimate the elastic modulus [3]. The bottom compartment is an airtight chamber, opened at the bottom by a 12mm diameter circular aperture lying on the soft tissues where a negative pressure can be applied to aspirate the tissues. The upper compartment holds a miniature digital camera which images the height of the deformation resulting from the aspiration. Measuring the deformation height corresponding to several steps of increasing negative pressures leads to an estimation of the behavior of the tissues using an inverse analysis based on a Neo Hookean model. To study the possible variations between subjects, LASTIC was used to estimate the elastic moduli of 16 healthy subjects, eight males and eight females, of different ages and body mass indexes (mean age = 29±6, mean BMI = 22±2). The initial Young's modulus of the cheek, cheekbone, forehead, and lower lip are respectively estimated to be in the range [31: 42kPa]. Significant intra-subject differences in tissue stiffnesses between the cheek and forehead and between the lower lip and forehead are highlighted by these estimations, and can be explained by the tissue thickness. They also show important inter-subject variabilities for some locations even when mean value stiffness show no statistical difference. This study stresses the importance of using a measurement device capable of evaluating the patient-specific tissue elastic moduli before and during an intervention in order to improve the accuracy of a surgery outcome. References 1. Chabanas M. et al. Comparison of linear and non-linear soft tissue models with post-operative CT scan in maxillofacial surgery. Computer Science, 2004, 3078:19-27. 2. Barbarino G. et al. Experimental and numerical study on the mechanical behavior of the superficial layers of the face. Skin Res Technol. 2011. 17:434-44. 3. Schiavone P. et al. In Vivo Measurement of Human Brain Elasticity Using a Light Aspiration Device. Medical Image Analysis, 2009, 13:673-678

Keyword

[ Softtissue ]

Contact

Emmanuel Promayon http://membres-timc.imag.fr/Emmanuel.Promayon

BibTex Reference

@InProceedings{LPP14,
   Author = {Luboz, V. and Promayon, E. and Payan, Y.},
   Title = {Measurements of the linear elastic properties of the face soft tissues using an aspiration device},
   BookTitle = {12th International Symposium on Computer Methods in Biomechanics and Biomedical Engineering, CMBBE14},
   Month = {October},
   Year = {2014}
}

EndNote Reference [help]

Get EndNote Reference (.ref)

Home Page Publications List Sorted Internship/Stages Teaching Contact
This page was automatically generated thanks to JabRef and bib2html , 8 February 2019